Technical characteristics
73
Display
Characteristics
OX 9062 - OX 9102 - OX 9104 - OX 9304
Display screen
LCD 7’’ TFT (colour display)
Backlighting by LEDs
Brightness
Continuous adjustment
Resolution
WVGA, or 800 pixels horizontally x 480 pixels vertically
Screen
saver
Choice of delays: 15', 30', 1h, or none
Display
without Zoom
Complete memory: 100,000
Horizontal
ZOOM
2500 pts out of the 100,000 of the complete memory
Display
modes
Vector
Envelope
Average
The entire acquisition
Points acquired, points interpolated, average
Linear interpolation between 2 acquired pts.
Display of the min. and of the max., on each abscissa, acquired on several bursts.
Over: no averaging, 2, 4, 16, 64
Display of all samples acquired in a burst with linear interpolation between 2 acquired
pts
Indications
on the screen
Triggering
Traces
Position of the triggering level (with coupling and overshoot indicator)
Position of the Trigger point on the bargraph and on the top edge of the screen (with
overshoot indicators)
Identifiers of traces, activation of the traces
Position, Sensitivity
Ground reference
High and low overshoot indicators, if traces outside screen
Various
Signal
for calibration of the 1/10
probes
Form: rectangular
Amplitude:
≈
0-3V
Frequency:
≈
1kHz
Connect the cold of the probe to the cold
of the calibration output of the probes.
Autoset
Search time
Frequency range
Amplitude range
Limits of duty cycle
<5s
>30Hz
15mVpp to 400 Vpp
from 20 to 80%
Summary of Contents for OX9302-BUS
Page 143: ...X04605B02 Ed 1 03 2018 ...