Functional Description
51
IP address
An IP address is coded in 4 bytes, displayed in decimal form
(
:
132.147.250.10
).
Each field can be coded between 0 and 255; the fields are separated by decimal points.
Unlike the physical address, the IP address can be modified manually by the user or
automatically by DHCP.
You must make sure that the IP address is unique on your network; if
an address is
duplicated, the operation of the network becomes problematical.
Subnetwork
mask
and Gateway
If the result of the "LOGICAL AND" between the IP address of the addressee of the
message and the value of the subnetwork mask (SUBNET MASK) is different from the
address of the addressee of the message, the message is sent to the gateway
(GATEWAY), which takes charge of getting it to its destination.
The mask and the address of the gateway can be programmed on the instrument.
DHC
protocol
This protocol is used to parameterize network access automatically.
A DHCP (Dynamic Host Configuration Protocol) server must be accessible in this network
(contact your network administrator to make sure of the presence of this type of server).
Each
ScopiX
instrument has a unique factory-configured MAC address. There is one wire
network MAC address and one WiFi address.
Selecting the
WiFi network
To connect to the WiFi network:
1.
"Scan" to manually scan the available
networks; done automatically when the
WiFi menu is opened.
2.
Select the SSID network.
3.
Enter the network's security key.
4.
Fill in the fields specific to the network, if
the manual mode is selected; otherwise
DHCP in the automatic mode.
5.
"Connect" to validate the parameters.
Selection of the
wire network
1.
Fill in the fields specific to the network, if
the manual mode is selected; otherwise
DHCP in the automatic mode.
2.
"Connect" to validate the parameters.
"
About" - (cf. p.17)