CALIBRATE SETUP MENU
METRIC
OIML
NIST
INDUSTRY
LEGAL STANDARD
MOTION BAND
INPUT
MOTION
BAND
(Limited to 255d)
STARTS
CALIBRATION
PROCEDURE
CALIBRATE MENU
CAL
STD CAL
SEALED
SWITCH
ENTER
MOTNBAND
STANDARD
ENTER
AUTO ZERO
MAINTENANCE
ENABLED
DISABLED
ENTER
INPUT
AZM RANGE
(Limited to 255d)
AZM
FINE CALIBRATION
APPLY
>25%
CAP
FINE CAL
TO SELECT LEGAL STANDARD
The STANDARD function allows the Model 3750 to be configured as required
by various regulatory agencies. The “INDUSTRY” selection is the default.
Choose “NIST” for US and Canadian Legal-for-Trade units. Choose “OIML” for
European LFT applications. “METRIC” is the same as “INDUSTRY” except
only kg and g units are enabled.
Note (Dual Load Cell Systems Only): The “STANDARD” menu is not available on Dual
Load Cell ABC Systems. The standard is fixed at “Industrial”.
Note: Before starting the following procedure, you must be in the Top Menu Level of
Calibration. See “Enable Calibration”.
Lega-For-Trade systems will modify this menu. The Print, Filter, Units, and Auto Total
(AUTO
∑
) may be added to the Calibration Setup Menu so they can be sealed. Informa-
tion on how these setup menus work are found in other sections of this manual.