M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 36
MSI-3750 Digital Weight Indicator
◆
User Guide
display overflow. The larger numbers can be printed through the use of the
button, or with a computer hookup.
AUTO TOTAL
SETUP Option, see “SETUP TOTAL” to enable Auto Total.
When the weight exceeds the Total Threshold the total function operates
automatically. The displayed weight is held in a holding register and added when
the weight returns below the Total Threshold. When a weight settles (no mo-
tion), the Total LED indicator will flash three times. If the weight changes to a
new settled value the LED will flash again indicating that the previous settled
reading has been replaced. The last settled reading is what will be used for
totaling when the scale returns below the Total Threshold. The user must make
sure that while removing the load the scale does not stabilize enough for a new
reading or an erroneous weighment addition could occur. The last settled weight
is actually added to the total when the scale returns to below the Total Thresh-
old. The “AUTOPEAK” total mode works the same, except that the highest
settled reading will be used for totaling on return to zero, rather than the last
settled reading.
Auto Total Operation
1)
Enable the Auto Total mode in the “SETUP TOTAL” menu (see “SETUP
TOTAL”). Select either the “AUTONORM” or the “AUTOPEAK” mode.
Exit from the setup menu.
2)
Use the
TOTAL
key to disable (“TOTALOFF”) or enable (“TOTAL ON”)
Auto Total.
3)
Place the weight to be totaled on the scale. The Total LED will flash three or
more times when the weight is settled. In high speed operations it is not
necessary to wait for the three flashes. The total is accepted when the first
flash appears.
4)
Remove the weight. The screen will read “x TOTAL” where x is the number
of totaled weighments.
Note: The total key is used as a Total On, Total Off, toggle key which is indicated briefly
on the message display (i.e. “TOTAL ON” or “TOTAL OFF”). Auto Totaling will only occur
in the TOTAL ON mode. The Auto Total On mode is indicated by an “AUTO
∑
” annuncia-
tor on the LCD. This feature allows the user to turn off Auto Total for periods in which the
scale needs to be used without adding to the total. Turning the Auto Total off does not
erase the current total. See “To Clear the Total Value” to learn how to erase the Total.
Rules for Auto Total:
1)
Cannot be in motion. An Auto Total acceptable reading is indicated by three
or more short flashes of the Total LED.
2)
Weight readings must be greater than the set Total Threshold.
3)
Each reading added to total must be preceded by a return to zero (Net or
Gross) or below the Total Threshold.
Summary of Contents for MSI-3750