M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 68
MSI-3750 Digital Weight Indicator
◆
User Guide
➀
EXIT
SETUP
!
SETUP
➀
EXIT
F2
SETPOINT
➁
ENTER
SETUP
➂
ENTER
NORMAL
√
EXIT
F2
GRADING
➄
ENTER
1)
Push
SETUP
followed immediately by the
SET POINTS
key (usually
F2
).
2)
Push the
ENTER
key. You are now in the
“SETUP SETPOINTS MENU.
3)
The “SP MODE” menu is the first selec-
tion. Push the
ENTER
key.
4)
You are now in the “SP MODE” menu. The
current mode is displayed. Use the
UP
or
DOWN
scroll key to select “GRADING”.
5)
Push
ENTER
to store your selection. You
are now back in the “SETUP SET
POINTS” menu.
6)
Use the “SET POINT ENTRY PROCE-
DURE” above to program all 8 set points to
the following settings:
≈
Set point 1: On, MODE = GROSS, MESSAGE = “<10”, VALUE = 10. Set the
DEAD ZONE to 0 on this and all subsequent set points.
Set point 2: On, MODE = GROSS, MESSAGE = “10–10.5”, VALUE = 10
Set point 3: On, MODE = GROSS, MESSAGE = “10.5–11”, VALUE = 10.5
Set point 4: On, MODE = GROSS, MESSAGE = “11–11.5”, VALUE = 11
Set point 5: On, MODE = GROSS, MESSAGE = “11.5–12”, VALUE = 11.5
Set point 6: On, MODE = GROSS, MESSAGE = “12–12.5”, VALUE = 12,
Set point 7: On, MODE = GROSS, MESSAGE = “12.5–13”, VALUE = 12.5
Set point 8: On, MODE = GROSS, MESSAGE = “>= 13”, VALUE = 13
∆
EXIT
SETUP
!
EXIT
SETUP
!
7)
Return to normal scale operation by
pushing
EXIT
twice after entering the last
set point (8)
Grading Setup Procedure
NOTE: When GRADING mode is selected, the “VALUE” entry skips the “GREATER” and
“LESSTHAN” entries. If the set points values were entered prior to enabling the “GRAD-
ING” mode the “GREATER” and “LESSTHAN” selections will be ignored.