Output Data Form:
The @Z Command combines data from all the ID Codes Statistics and prints
them in a formatted form. This output can be quite lengthy depending on the
number of ID Codes in use. Only ID Codes that have at least one Total weigh-
ment will print.
@1
DATA FROM SCALE A
@2
DATA FROM SCALE B
@3
DATA FROM SCALES A+B
@4
DATA FROM SCALES A–B
These @ commands are unique to the Dual Load Cell (ABC) Meter.
Purpose:
Use the @1, @2, @3, and @4 commands in conjunction with the @Vx or @Wx
commands to cause the print string to take data from one of the four weight
modes. When preceded by the @1-4 command, do not use the @ sign in front of
the weight command; e.g. @1W3. If the @W or @V commands are used without
the @1-4 in front, the scale mode currently displayed will provide the data.
Input Data Form (examples, any W or V command will work):
@1W1 Print the Weight in the last display mode of Scale A.
@2V2
Print the Gross Weight of Scale B.
Output Data Form:
Is dictated by the suffix command, see “@W” and “@V”.