To Change the UNITS
SETUP UNITS
Enables the desired weight units for activation by the
UNITS
key. For example,
if an operator only wants pounds and kilograms activated, all other units can be
disabled. This Menu is moved to the Calibrate Setup menu in NIST and OIML
units.
Note: This operation requires that one of the Function Keys is setup as the
UNITS
key.
To Enable/Disable UNITS
UNITS
F5
KILOGRAM
UNITS
F5
SHORTTON
Push
UNITS
(Usually
F5
). The displayed
weight will change to the next activated
unit. If more than two units are activated,
pushing the
UNITS
key will rotate through
the available choices.
1)
Push the
SETUP
key followed immedi-
ately by the
UNITS
key (usually
F5
). The
menu will display “UNITS”
Tons available on capacities 2,000 lb and over.
Metric Tons available on capacities 1000 kg and
over. lb-oz, oz, and g available on scales 250 lb
and under.
2)
Push
ENTER
. The unit POUNDS will
appear.
3)
The numeric display will read “On” if the
displayed unit is activated or will read
“OFF” if it is inactivated. Use the
LEFT
or
RIGHT
Cursor keys to change the status of
the displayed unit from “On” to “Off”
4)
Use the
UP
Scroll key to scroll through all
the available UNITS and use the
LEFT
or
RIGHT
Cursor keys to enable (On) or
disable (OFF) the unit as desired.
Note: If the user attempts to disable all units,
Pounds will automatically be enabled. OIML
units are limited to kg, g, and metric Tons.
5)
When finished selecting units, push
EXIT
to return to normal scale operation.
➀
EXIT
SETUP
!
SETUP
➀
UNITS
F5
UNITS
➁
ENTER
➂
F4
√
UV
F3
KILOGRAM
Scroll Through Available units
√
UV
F3
GRAMS
≈
EXIT
SETUP
!