MSI-3750 Digital Weight Indicator
◆
User Guide
Page 67
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
➀
EXIT
SETUP
!
SETUP
➀
EXIT
F2
SETPOINT
➁
ENTER
SETUP
➂
ENTER
NORMAL
√
EXIT
F2
DISABLED
➄
ENTER
≈
EXIT
SETUP
!
1)
Push
SETUP
followed immediately by the
SET POINTS
key (usually
F2
).
2)
Push the
ENTER
key. You are now in the
“SETUP SETPOINTS MENU.
3)
The “SP MODE” menu is the first selec-
tion. Push the
ENTER
key.
4)
You are now in the “SP MODE” menu. The
current mode is displayed. Use the
UP
or
DOWN
scroll key to select “DISABLED”.
5)
Push
ENTER
to store your selection. You
are now back in the “SETUP SET
POINTS” menu.
6)
Push
EXIT
to return to normal scale
operation.
To Disable all Set Points
You must enable the set point menus to proceed. See procedure above.
To re-enable all the Set Points
Follow steps 1-5 above except on step 4 select the “NORMAL” (or GRADING)
mode. This does not override the settings of each set point. You must enable
them individually if they were in the “OFF” condition.
USING THE MSI 3750 AS A GRADING SCALE
The MSI 3750 with or without the Set points relay option, can be set up as a
multiple zone (up to 8) grading scale. The relay outputs can be connected to
grading lights, or to automatic bins. In this example the 3750 will be used to
grade in 6 zones, with additional over and under zones for a total of 8. In this
example our grading zones are: <10 lb, 10 to 10.5 lb, 10.5 to 11 lb, 11 to 11.5 lb,
11.5 to 12 lb, 12 to 12.5 lb, 12.5 to 13 lb, and
≥
13 lb. Also, by programming the
optional “MESSAGE”, the display gives an indication of the Grade, removing
the need for any external lights or bins, etc., in a manual grading operation.
Summary of Contents for MSI-3750