M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 32
MSI-3750 Digital Weight Indicator
◆
User Guide
To Change the Numeric Display Mode
Use of the “DISABLED” mode can cause confusion as the weight reading
blanks out. Be sure this is what you want to do before disabling the
display. If the numeric display is blanked out, push the
SETUP
key twice,
up key to NUM DISP, push
ENTER
, up key to “NORMAL”, push
ENTER
,
push
EXIT
to return to normal operation.
!
CAUTION
1)
Push
SETUP
followed immediately by the
ID#
key. The message reads “ID NUMBR”.
2)
Push
ENTER
to access the menus.
3)
Push
UP
until the message reads
“NUM DISP”.
4)
Push
ENTER
. The message indicates the
first “NUM DISP” menu choice – “NOR-
MAL”.
5)
Select the “NORMAL”, “PERCENT”, or
“DISABLED” display modes by using the
UP/DOWN
keys to scroll through the
choices. In this example, we’ll pick the
“PER CENT” mode.
6)
Push
ENTER
to set the Number Display
mode.
7)
You are back in the SETUP ID# menu.
Return to normal scale operation (in PER
CENT) by pushing
EXIT
.
➀
EXIT
SETUP
!
SETUP
➀
F1
ID#
ID NUMBR
➁
ENTER
ID NAME
➂
UV
F3
NUM DISP
√
ENTER
NORMAL
➄
UV
F3
PER CENT
≈
ENTER
NUM DISP
∆
EXIT
SETUP
!
NUM DISP
The function of the numeric (weight) display can be modified. The “NORMAL”
setting displays standard NET or GROSS weight. The “PERCENT” setting turns
the numeric display into a percentage weight meter. In the PERCENT mode, the
0% and 100% values are determined by the BARGRAPH settings (see
“BARGRAPH MENU” for setting the 0% and 100% values). You must set the
0% and 100% values for the PERCENT mode to function. The “DISABLED”
mode turns off the weight display altogether. This would be used when only the
bargraph is desired or the meter is used to check set points only.
Summary of Contents for MSI-3750