M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 104
MSI-3750 Digital Weight Indicator
◆
User Guide
STATISTICAL VALUE
1
2
3
4
5
6
7
8
GRAND TOTAL WEIGHT
1
2
3
4
5
6
7
8
9
10
GRAND NUMBER OF SAMPLES
1
2
3
4
5
6
7
8
9
10
@X
PRINT STATISTICS VALUE ONLY (requires Statistics Option)
Purpose:
Use the @X command to print the statistics of the current ID Code. Numeric
value only, no description text.
Input Data Form:
@X1
Average weight
@X2
Minimum weight
@X3
Maximum weight
@X4
Standard Deviation
@X5
Coefficient of Variance (%)
@X6
Grand Total
@X7
Grand Total Average
@X8
Grand Total Number of Samples
Output Data Form:
@X1 @X2 @X3 @X4 @X5 @X7
-
2 0 .
5 0 2
Length: 8
Justification: right justified
@X6
1 2 3 4 5 6 7 .
0 5
Length: 10 Justification: right, leading zeros suppressed
@W8
1 2 3 4 5 6 7 8
Length: 10 Justification: right, leading zeros suppressed
@Y
PRINT STATISTICS FULLY (requires Statistics Option)
Purpose:
Use the @Y command to print the statistics of the current ID Code with text
descriptor.
Input Data Form:
@Y1
Average weight
@Y2
Minimum weight
@Y3
Maximum weight
@Y4
Standard Deviation
@Y5
Coefficient of Variance (%)
@Y6
Grand Total
@Y7
Grand Average
@Y8
Grand Number of Samples
Summary of Contents for MSI-3750