background image

IMI+70-XF-XC-XP-XT Issue 7 

2400 & 1400 Series (XP, XT, XC & XF) 

Flame Proof Camera Housings 

& Pan Tilt Units

 

 

Installation & Maintenance Instructions

This manual should be read before attempting to connect or operate the equipment

 

This equipment shall be installed in accordance with the latest local/national codes of practice, and standards  

eg :- 

BS EN 60079-14:2014  Explosive atmospheres – Part 14: Electrical  installations design, selection and erection 

(IEC 60079-14:2013) 

IECEx/ATEX Certified 

II 2 G Ex db IIC 
II 2 D Ex tb IIIC

 

Whilst every effort has been made to ensure that all information in this document is correct at the time of 

publication, due to our policy of continuous improvement, the company reserves the right to change any 

information contained herein without notice or reference.  

With the exception to Annexe B which must be referred to the certification Body. 

Summary of Contents for 2400 Series

Page 1: ...eg BS EN 60079 14 2014 Explosive atmospheres Part 14 Electrical installations design selection and erection IEC 60079 14 2013 IECEx ATEX Certified II 2 G Ex db IIC II 2 D Ex tb IIIC Whilst every effo...

Page 2: ...ue 2 0 09 03 2016 Inclusion of Annexes 3 0 05 04 2016 Inclusion of Ex ia removal of ratings page 5 Additions to annexe E 4 0 06 04 2016 Change in Harmonised standard issues 5 0 01 09 2016 Change Cert...

Page 3: ...on 11 3 3 2 Washer Nozzle Installation 12 3 4 Electrical Installation 13 3 4 1 Electrical Installation XP XT Integrated Pan Tilt housing assembly 13 3 4 2 XP XT Common Connection Examples 14 3 4 3 Ele...

Page 4: ...II of ATEX Directive 2014 34 EU 7 Be aware that aggressive substances may require extra protection of the equipment to maintain its integrity and explosion protection 8 The equipment may need additio...

Page 5: ...indow is made with toughened glass or in the case of the Thermal Imager and Dual Imager versions is made from Infra red transparent material and which is factory fitted with a mechanical window guard...

Page 6: ...iled connection and configuration of units the installer should refer to individual project specific drawings and information In addition to this manual there are various addendums available that cove...

Page 7: ...weight of the complete unit Do not stand or place objects directly under installed system Due care must be taken to ensure sufficient clearance is allowed to permit full rotation of the unit with its...

Page 8: ...EATON Installation Maintenance Instructions IMI 70 XF XC XP XT Issue 7 2016 Eaton Page 8 of 21 Fig 1 XP26VW Example XP Series unit showing base mount fixing points Fig 2 BPW6800 Wall Bracket...

Page 9: ...tion Maintenance Instructions IMI 70 XF XC XP XT Issue 7 2016 Eaton Page 9 of 21 Fig 3 XC40VW Example XC Series unit showing shaft mount fixing points Fig 5 BFP0600 900 1200 Column Spacer Fig 4 BFW500...

Page 10: ...e a mounting plate on the bottom of the housing tube that have four 4 No M6 Threaded fixing points Fig 6 The type and size of these fixings to be supplied by the user installer and must be suitable fo...

Page 11: ...ved prior to installation The correct sunshield fixings for each model are supplied with the camera system and should be positioned as detailed below To mount the sunshields first they must be positio...

Page 12: ...ble washer nozzle and mounting bracket These should be fitted during installation with the supplied fixing and positioned to allow cleaning fluid to reach the camera housing window when the wash comma...

Page 13: ...Voltage 3 4 1 Electrical Installation XP XT Integrated Pan Tilt housing assembly 1 Always use colour coded conductors or other identification of conductors for ease of wiring and identification of fu...

Page 14: ...DATA A DATA B 230VAC L VIDEO SCREEN VIDEO SIGNAL 110VAC N DATA A DATA B 110VAC L VIDEO SCREEN VIDEO SIGNAL 24VAC N DATA A DATA B 24VAC L VIDEO SCREEN VIDEO SIGNAL 230VAC MODEL WITH NO PUMP OUTPUT 110V...

Page 15: ...se order for as built wiring and connection details of the unit Warning This cover must not under any circumstances be removed until at least 5 minutes after the disconnection of power source To gain...

Page 16: ...AC PUMP SUPPLY N 24VAC PUMP SUPPLY VIDEO DIRECT TO CAMERA 24VAC MODEL WITH PUMP OUTPUT J1 TH HEATER 22 O 10W HEATER 22 O 10W J3 J2 24VAC N DATA A DATA B 24VAC L NC EARTH SWITCH L 24VAC PUMP SUPPLY N 2...

Page 17: ...sher nozzle Check and if necessary replace the window wiper blade assembly Please read and be familiar with the instructions before servicing the Pan Tilt or housing 4 1 Corrosion Protection Although...

Page 18: ...nyl and affixed product The contents of the label will be in ENGLISH The label shows A Name of Manufacturer B Model Type and reference C Operating Voltage D EX ratings E ATEX Certificate IECEX certifi...

Page 19: ...4 x M10 fixings on 182mm pcd Standalone housing Depending on mounting brackets Supply voltage 24VAC 50 60Hz or 100 to 230VAC with integral transformer Power consumption Max 120 Watts depending on mod...

Page 20: ...impedance of 50 and have a minimum degree of protection IP6X If the antenna utilizes a wire conductor the minimum diameter shall be 0 1mm Alternatively if a track antenna is used the tracking shall ha...

Page 21: ...indow assemblies integrity of the welded construction shall also be verified during routine overpressure testing Empty enclosures may be tested The individual parts of a flameproof enclosure for examp...