MSI-3750 Digital Weight Indicator
◆
User Guide
Page 11
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
To Clear Tare and return to GROSS mode
To Keyboard Tare
(
TARE
key function must be set to “KBD/UPDN”)
1)
Push
TARE
followed by
CLR
(
ZERO
).
The message display reads “TARE CLR”.
The scale returns to the GROSS mode.
Alternate method: Remove all weight from
the scale (Gross Zero) and push
TARE
.
The message display temporarily reads
“TARE CLR”. Then the scale returns to the
GROSS mode.
➀
TARE
T
ASCII
➁
ZERO
0
1)
Push
TARE
. The display reads “TARE”.
Any current Tare value is displayed.
2)
Using the numeric keys input the value
desired. In this example we’ll use 0.5 lb as
a Tare Value.
Note: The 3750 will automatically place a
leading zero if the Tare value starts with the
decimal point.
3)
The Tare Value “0.5” is displayed. Push
ENTER
to place the value in the Tare
Register. The display reads “TARE SET”
and displays the Tare value for 1 second.
All subsequent readings have the Tare
value subtracted and are displayed in
“NET” weight.
➀
TARE
T
ASCII
➁
F1
➁
5
MNO
➂
ENTER