M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 110
MSI-3750 Digital Weight Indicator
◆
User Guide
Causes the current print format
strings to be printed.
1=Print Comm 1 string
2=Print Comm 2 string
3=Print Both
PR
Calendar Date
Set
Example: RD10/05/01; Is equal to
October 5th, 2001
Enter date in MM/DD/
YY order
RD
Real Time
Clock/Calendar
Enable
Turns on Clock Calendar when
power is off and enables scale-off
data reception
1=Disabled
2=On
RE
Real-Time
Clock Display
Mode
Formatting for LCD Clock mode
only, see @T for time formatting
the print or output.
1=12HR/MIN
2=12HR/MIN/SEC
3=24HR/MIN
4=24HR/MIN/SEC
RM
Real Time
Clock Set
Example: RT22:35:55; is equal to
10:35:55 PM
Enter time in
HH:MM:SS
RT
Day of Week
Set
1=Sunday 2=Monday
3=Tuesday 4=Wednesday
5=Thursday 6=Friday
7=Saturday
RW
Set Point
Receive Data
Enable
S#1 to S#8 enables each set point.
The last enabled set point receives
any set point data or parameters.
1-8 for Set Points 1
through 8
S#
Set Point Dead
Zone Value
Terminate weight value with a
semicolon or another command.
Enter value in current
units
SD
Description
Comments
Suffix (Bold text indicates default)
Command
General Set
Points Mode
Enable
1=Disabled
2=Normal
3=Grading
SE
Set Point Latch
0=Off
1=On
SL
CommPort
Quiet Off
Releases data held in buffers.
Cancels the QU command
1=CommPort1
2=CommPort2
QI
CommPort
Quiet On
Hold serial data in buffers. Used for
networking.
1=CommPort1
2=CommPort2
QU