M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 66
MSI-3750 Digital Weight Indicator
◆
User Guide
➀
EXIT
SETUP
!
SETUP
➀
EXIT
F2
SETPOINT
➁
ENTER
➂
EXIT
F2
➠
➂
EXIT
F2
√
F5
➄
EXIT
SETUP
!
1)
Push
SETUP
followed immediately by the
SET POINTS
key (usually
F2
).
2)
Push the
ENTER
key. You are now in the
“SETUP SETPOINTS MENU.
3)
Use the
UP
or
DOWN
key to scroll to the
set point (1-8) you wish to enable or
disable.In this example we’ll enable set
point 2, but the procedure applies for any
set point.
4)
Use the
LEFT
or
RIGHT
cursor key to
enable the set point. Dual Input 3750s: Use
the
LEFT
or
RIGHT
Cursor keys to select
A, B, A or B., A Ad b (Summed A+B).
5)
Push
EXIT
to return to normal scale
operation or use the
UP
or
DOWN
keys to
scroll to other set points.
ENABLING / DISABLING SET POINTS
It is often useful to be able to set up a set point ahead of time and disable it for
testing purposes.
To Enable or Disable a SINGLE Set Point