M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 64
MSI-3750 Digital Weight Indicator
◆
User Guide
13
ENTER
14
2
DEF
2_
15
ENTER
DELAY
16
UV
F3
MESSAGE
17
ENTER
18
Refer to secton 7 for text entry
procedures.
19
F4
19
UV
F3
COMPORT2
19
UV
F3
SCREEN
20
ENTER
MESSAGE
21
EXIT
F2
DISPLAY
22
ENTER
NORMAL
13) Push
ENTER
. The “SPx DLAY” (where
‘x’ is 1-8) entry screen will appear.
14) Use the Numeric keys to input the delay
time in seconds. 1 to 1500 seconds.
In this example we’ll enter a 2 second delay
which delays the set point responses. Note:
If you input a number larger than 1500 the
message “TOO BIG” will appear.
15) Push
ENTER
to set the delay time.
16) This step is Optional, skip to step 21 if a set
point Message is not needed. Push the
UP
key to the “MESSAGE” menu.
17) Push
ENTER
. The message entry screen
will appear.
18) Use the
ALPHA
, 1-9 and
ENTER
keys to
input a message up to 20 characters. You
can include “@” codes for printing current
weight, time, and date with the set point
message. See the Comm Port Section 7 for
details on entering the message. Refer to
section 7 for text entry procedures.
19) After the text entry, you can assign the
message to Commport1, Commport2, and/
or the LC Display “SCREEN”. Use the
UP
key to see the message assign choices. Use
the
LEFT
Cursor key to change from
“OFF” to “ON”.
20) After you have set all the message assign-
ments, push
ENTER
to finish.
21) This step is Optional, skip to step 23 if
blinking or blanking the display is not
needed. Next, tell the set point how to
display when the set point turns on. Use the
DOWN
key to move to the “DISPLAY”
menu.
22) Push
ENTER
.The first menu choice will be
the last set mode. In this case, the
“RESPONSE” was set to “NORMAL”.
Summary of Contents for MSI-3750