MSI-3750 Digital Weight Indicator
◆
User Guide
Page 59
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
➀
UV
F3
➠
➀
UV
F3
SETUP
➁
ENTER
DISABLED
➂
EXIT
F2
GRADING
➂
EXIT
F2
NORMAL
√
ENTER
➀
EXIT
SETUP
!
SETUP
➀
EXIT
F2
SET
➁
ENTER
1)
Push
SETUP
followed immediately by the
SET POINTS
key (usually
F2
).
2)
Push the
ENTER
key. You are now in the
Setup Set Points Menu.
1)
If necessary, use the
UP
or
DOWN
key to
scroll to the “SP MODE” menu.
2)
Push the
ENTER
key. You are now in the
“SP MODE” menu. The current mode is
displayed.
3)
Use the
UP
or
DOWN
scroll key to select
the desired set point mode; NORMAL,
DISABLED, or GRADING.
In this
example we will enable the set points as
“NORMAL”.
4)
Push
ENTER
to store your selection. You
are now back in the “SETUP SET
POINTS” menu. Use the
UP/DOWN
keys
to select the next set point menu or push
EXIT
to return to normal scale operation.
Setup Set Points Menu Entry Procedure
SP MODE
The SP MODE (All Set Points Mode) menu selection provides the Master
enable/disable of set points. In addition, the set points can be configured in a
“GRADING” mode, where each set point represents a grade threshold. The set
points must be enabled in this menu to function.
All Set Points Mode Procedure
You must first be in the SETUP SET POINTS menu to proceed. See procedure above.
Summary of Contents for MSI-3750