5-5
Drain PuMP MOTOr
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
See page 4-29 for the procedure for accessing
the drain pump motor.
To check the drain pump at the component
terminals, perform the following steps.
Unplug washer or disconnect power.
Disconnect the wire connector from the
drain pump.
Set the ohmmeter to the R X 1 scale.
Touch the ohmmeter test leads to the drain
pump terminals. The meter should indicate
approximately 12.3 ohms.
1.
2.
3.
4.
To check the drain pump at the CCU, perform
the following steps.
Unplug washer or disconnect power.
Disconnect the drain pump connector DP2
(See page 4-34) from the CCU.
Set the ohmmeter to the R X 1 scale.
Touch the ohmmeter test leads to connector
pins 1 and 2. The meter should indicate
12.3 ohms.
1.
2.
3.
4.
1 2
Drain Pump
Connector
Connector DP2 At CCU