4-53
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Open dryer console cover (See page 4-52).
Lift the locking tab and disconnect the Rast
connector from the CCU to the UIC.
Disconnect the P8, P9, and P14 wire
connectors by depressing the locking tabs
and pulling the connectors off the control.
Disconnect K2 Power Relay wire connector
by pulling the connector off the control.
nOTe:
Use an anti-static wrist strap
whenever handling electronic control boards
or use other precautions to avoid ESD
damage to the circuitry.
1.
2.
3.
4.
reMOve Dryer COnTrOl BOarD (CCu)
Press two locking tabs just enough to
release one edge of the board.
Remove it from under the tabs on the other
edge of the board.
5.
6.
Locking Tabs
Locking Tabs