4-19
Unplug washer or disconnect power.
Turn off the water supply to the washer.
Remove dryer from stack (See page 4-11).
Remove the screw from the green ground
wire.
Pull the L1 and neutral wire connectors off
the spade terminals of the RFI line filter.
Pull the washer away from the wall far
enough to access the power supply cord on
the rear panel.
1.
2.
3.
4.
5.
6.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
reMOve WaSHer POWer COrD (Mle MODel Only)
Remove the 1/4” hex head screw that
secures the power supply cord strain relief
to the rear panel of the washer.
Push the wire connectors out the rear panel
of the washer.
7.
8.
2 Wire
Connectors
Ground Wire Screw
1/4” Hex
Head Screw