5-13
When the gas is on, the amount of water
column present is equal to the total amount
of deflection shown in the manometer.
Once the test is completed, make sure
the tapered fitting is removed from the gas
valve and the plug is repositioned into the
gas valve and resealed with pipe seal.
Check for gas leaks again with a soap or
bubble solution. DO NOT USE OPEN
FLAME TO CHECK FOR GAS LEAKS.
IF HIGH WATER COLUMN PRESSURE IS
DETECTED: the gas flame can damage
the flame spreader on the burner. (This can
be caused by the wrong orifice, improper air
mixture or high gas pressure. If pressure
is higher than expected, contact the local
gas utilities company to check the outside
regulator.
9.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
How to use:
Disconnect power supply to dryer.
Remove front panel.
Shut off gas to dryer.
Install a 1/4” tapered fitting at the gas valve
pressure tap. Use thread seal tape or
compound on fitting.
Fill the manometer tube with water until
each side equalizes at “0” water column.
Push the end of the manometer hose onto
the pressure tap located on the gas valve.
Connect hose to one end of the manometer.
Turn on the gas and reconnect dryer to
power. Run the dryer in a heat cycle. Read
the manometer with the burner ON, (check
for gas leaks).
1.
2.
3.
4.
5.
6.
7.
8.
Pressure
Tap
Barbed
Pressure Tap
Smooth
Pressure Tap
1/4” Tapered
Fitting