4-85
Remove the control panel bracket
(See page 4-10).
Remove gas burner assembly
(See page 4-84).
Insert a 3/8” hex wrench into gas valve.
Turn fitting counterclockwise to unscrew it
from gas valve.
nOTe:
Use an appropriate sealant (rated
for natural gas or LP depending on fuel
type) during reassembly of this gas valve
fitting.
1.
2.
3.
4.
Remove three 1/4” hex head screws from
bottom of bracket.
Remove gas valve body from bracket.
Gas valve orifice is now accessible and can
be removed with a 3/8” wrench.
nOTe:
Do not use sealant on threads of the
orifice as it can block the gas flow and it is
not needed.
TeCH TiP:
When replacing a gas valve
assembly it is always prudent to remove the
orifice from the original gas valve and install
it on the new valve. This helps avoid having
the wrong size orifice on the dryer after a
gas valve replacement.
nOTe:
All replacement gas valves for this
dryer come set for natural gas use. When
working on a dryer that uses LP gas, the
valve will need to be reconfigured. See
instructions with the LP kit.
5.
6.
7.
Gas Valve
Fitting
Three 1/4” Hex
Head Screws
reMOve GaS valve FrOM BraCkeT
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.