6-7
ACCU
TRAC
®
WASHER
INDICATION DISPLAY
EXPLANATION AND RECOMMENDED PROCEDURE
COIN 2 ERROR
The Coin 2 sensor is detected as blocked
for 8 seconds.
Possible Causes
– Coin vault full of money.
– Blocked or dirty sensor.
Procedure
1. Clear error code.
2. Unplug the washer or disconnect power.
3. Clean the coin sensor.
4. Check for blocked coin sensor switch on coin drop.
d13 only occurs with coin 2 installed. If the above
procedures do not solve the problem, replace the UIC.
GENERATION 2 DEBIT CARD
READER ERROR
No communication from installed debit card reader
in Generation 2 debit mode for 5 minutes.
Possible Causes
– Card reader Gen 2 not installed, when washer
is in Ed mode.
– Poor contact or communication cable not
connected between UIC (AA3) and the card reader.
– Card reader failure.
Procedure
1. Clear error code.
2. Unplug the washer or disconnect power.
3. Check the wire harness connections between User
Interface (AA3) and the debit card reader Gen2. Do
continuity test on cable.
4. Make sure you are using a Gen2 card reader.
5. Reconnect power and wait for 5 minutes.
If the above procedures do not solve the problem,
replace the UIC.
d
1 3
d
1 3
d
1 6
d
1 6
Critical errors are indicated as part of the ‘out
of order’ message.
nOTe:
Errors d5, d13, and d16 will not stop
the ongoing cycle, although they will not
allow another cycle to begin until the error is
addressed.
Summary of Contents for MLE20PDAYW0
Page 14: ...1 6 NOTES ...
Page 21: ...2 7 Stacked Washer Gas Dryer Grounding ...
Page 40: ...2 26 NOTES ...
Page 56: ...3 16 NOTES ...
Page 144: ...4 88 NOTES ...
Page 198: ...6 32 NOTES ...
Page 203: ...7 5 NOTES ...
Page 204: ......