4-20
Use a small flat blade screwdriver in the
loop at one end of the spring, and pull to
expand the spring. Remove the retaining
wire from the groove securing the bellow to
the washer front panel.
Push the right side of the bellow into the
cabinet opening.
5.
6.
Bellow
Retaining Wire Tension Spring
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Unplug washer or disconnect power.
Turn off the water supply to the washer.
Open the washer door.
Remove two T-20 screws that secure the
door lock assembly to the front panel of the
washer.
nOTe:
These screws are different than
other screws on the washer and need to be
reinstalled to remount the lock assembly
properly.
1.
2.
3.
4.
reMOve DOOr lOCk / SWiTCH aSSeMBly
Door Lock Assembly
Two T-20 Screws