4-9
Open the control panel (See page 4-3).
Press the locking tab and remove the
membrane switch ribbon connector from the
control board.
Remove the remaining two T-20 security
screws that secure the keypad facia to the
control panel. Support the facia so it will not
fall when the last screw is removed.
1.
2.
3.
Squeeze the securing clips that hold the
keypad assembly inside the control panel
cover. (See first photo in left column).
Remove the keypad assembly from the front
of the control panel cover.
The keypad assembly consists of a back
plastic plate with an elongated peg and a
round peg to position the membrane switch
and 9 push button plate on.
The front plate snaps into clips around the
edge of the back plate, which encloses
and secures the push button plate and
membrane switch in position.
4.
5.
6.
7.
reMOve keyPaD aSSeMBly
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Two T-20
Security Screws
Ribbon Connector
Locking Tab
Keypad
Securing Clips