6-24
• If the resistance reading goes from infinity
to a few ohms as pulley arm closes the
switch, belt switch is OK. If not, replace the
belt switch.
• If belt switch is OK and there is still an
open circuit (infinite Ω), check and repair the
wiring harness.
• If the Start winding is in question and the
resistance is much greater than 4Ω, replace
the motor.
Door Switch problems can be uncovered in
the Door Switch Diagnostic Test; however,
if this was not done, the following can be
done without applying power to the dryer.
Connect an ohmmeter across P8-3 (neutral,
white wire) and P8-4 (door, tan wire).
• With the door properly closed, the
ohmmeter should indicate a Closed circuit
(0–2Ω).
• If not, replace the door switch assembly.
1.
2.
TeST #3 Heater Test
This test is performed when either of the
following situations occur:
Dryer does not heat
Heat will not shut off
This test checks the components making up
the heating circuit. The following items are
part of this system:
Part of Heating system
Electric
Dryer
Gas
Dryer
Harness / connection
yes
yes
Heater relay
yes
yes
High temp cutout
yes
yes
Thermal fuse
no
yes
High temp thermostat
yes
yes
Heat element assembly
yes
no
Gas burner assembly
no
yes
Centrifugal switch
yes
yes
Exhaust thermistor
yes
yes
Machine control electronics.
See page 1-1 ESD.
yes
yes
Console electronics and
housing assembly
yes
yes
Gas supply
no
yes
•
•