5-2
PreSSure SWiTCH
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
See page 4-16 for the procedure for
accessing the pressure switch.
To check the pressure switch at the
component terminals, perform the following
steps.
Unplug washer or disconnect power.
Disconnect the wire connector and hose
from the pressure switch.
Set the ohmmeter to the R X 1 scale.
Touch ohm meter leads to terminals 21 &
22, continuity will be read without water in
the washer. As water enters the washer
the next switch to close is Suds Level
and continuity is read between terminals
11 & 14. The next switch to close is the
Wash Level read at terminals 21 & 24.
Finally if water were to rise high enough,
the Overflow Switch would close between
terminals 21 & 26.
1.
2.
3.
4.
To check the pressure switch at the CCU,
perform the following steps with no water in
the washer.
Unplug washer or disconnect power.
Disconnect pressure switch connector PR6
from the CCU (See page 4-34).
Set the ohmmeter to the R X 1 scale.
Touch the ohmmeter test leads to connector
pins 4 and 6. The meter should indicate
continuity.
Water level setting
Test points
Less than 1 liter
Pins 4 and 6
Suds Level > 3.6 liters
Pins 1 and 2
Wash Level > 5.4 liters
Pins 4 and 5
Overflow, about 54 liters
Pins 3 and 4
1.
2.
3.
4.
Hose Inlet
Summary of Contents for MLE20PDAYW0
Page 14: ...1 6 NOTES ...
Page 21: ...2 7 Stacked Washer Gas Dryer Grounding ...
Page 40: ...2 26 NOTES ...
Page 56: ...3 16 NOTES ...
Page 144: ...4 88 NOTES ...
Page 198: ...6 32 NOTES ...
Page 203: ...7 5 NOTES ...
Page 204: ......