4-63
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Open dryer door and remove lint filter.
Remove three star head screws.
nOTe:
The middle screw is shorter than
the other two. The outer two screws are
large pan head screws, longer than any
other star head screws in the dryer.
1.
2.
reMOve Dryer OuTleT Grill
Lift outlet grill off front bulkhead.
Separate the two halves of the outlet grill by
pulling them apart.
The lint filter door has a spring, on one
end of the door, that keeps it closed. This
keeps item from being drawn down into the
blower if the dryer is operated without the
lint filter.
3.
4.
5.
3 Star Head
Screws
Lint Filter
Door Spring