Scala2 | Version 5 | System Configuration
Receiving Warp Lengths from Scantrol
You can output warp length data from Scantrol iSYM Trawl Control application to Scala2 software.
About this task
Note:
In this procedure, data are transmitted via a UDP port but a connection via a serial
port can be possible.
Procedure
1.
Scantrol and Marport computers must be connected together via an Ethernet wired network.
Both computers must be on the same sub-network to communicate with each other:
192.168.0.XX.
For example, the network IP address can be set at
192.168.0.10
on Scantrol computer and at
192.168.0.12
on Marport computer. The subnet mask address is 255.255.255.0 for both.
2.
Go to iSYM's
Configure Communication Ports
menu, then in
13: NMEA UDP 1
enter a port
number, such as
9000
, and set
SEND
to
1
.
Note:
The port number must be different from the one on which Scala2 sends data (if
applicable).
3.
In Scala2, open the control panels then click
NMEA Inputs
>
Add input
.
4.
Set a UDP connection and enter the corresponding port.
42
Summary of Contents for Scala2
Page 1: ...Scala2 User Manual...
Page 2: ......
Page 20: ...Scala2 Version 5 Installation 19...
Page 28: ...Scala2 Version 5 System Configuration Single Trawl Gear Twin Trawl Gear Triple Trawl Gear 27...
Page 29: ...Scala2 Version 5 System Configuration Quadruple Trawl Gear Twin Outrigger Trawl Gear 28...
Page 30: ...Scala2 Version 5 System Configuration Port Seine Gear Starboard Seine Gear 29...
Page 69: ...Scala2 Version 5 System Configuration 68...
Page 105: ...Scala2 Version 5 Display Configuration 104...
Page 122: ...Scala2 Version 5 Display Configuration 121...
Page 156: ...Scala2 Version 5 Maintenance and Troubleshooting c Double click UninstallScala command 155...