Scala2 | Version 5 | Maintenance and Troubleshooting
Problem
Possible causes
Solution
Ethernet
connection is
down.
1.
Click
Menu
>
Expert Mode
and enter the
password
copernic
.
2.
Open the control panels and go to the
Mx
panel.
Click the menu icon next to the name of the receiver
and click
Configure Receiver
.
3.
From the system setting page, check on the schema
at the bottom is there are green checks.
4.
If there is a red cross, check that the power supply
for PoE adapter is connected to the mains supply.
5.
From the system page, click
Hydrophones
from the
panel on the left.
6.
Check the hydrophones current status. If there is no
current:
1.
Check from the configuration page that the
correct hydrophone type between passive and
active is selected.
2.
Check that the wiring in the hydrophone junction
box is correct.
A VMware Fusion
message appears
when adding a new
USB key.
This message is
due to the virtual
machine that is
installed on your
computer with
Scala2. It appears
when adding an
external USB
device.
1.
Select
Remember my choice and do not ask again
.
2.
Click
Connect to Mac
.
The size of Scala2
window is smaller
than before.
Scala2 window
must have lost
the full screen
display.
Double-click the top of the window to have a full
screen window.
146
Summary of Contents for Scala2
Page 1: ...Scala2 User Manual...
Page 2: ......
Page 20: ...Scala2 Version 5 Installation 19...
Page 28: ...Scala2 Version 5 System Configuration Single Trawl Gear Twin Trawl Gear Triple Trawl Gear 27...
Page 29: ...Scala2 Version 5 System Configuration Quadruple Trawl Gear Twin Outrigger Trawl Gear 28...
Page 30: ...Scala2 Version 5 System Configuration Port Seine Gear Starboard Seine Gear 29...
Page 69: ...Scala2 Version 5 System Configuration 68...
Page 105: ...Scala2 Version 5 Display Configuration 104...
Page 122: ...Scala2 Version 5 Display Configuration 121...
Page 156: ...Scala2 Version 5 Maintenance and Troubleshooting c Double click UninstallScala command 155...