Scala2 | Version 5 | System Configuration
Product
reference
Name
Use case
Bandwidth
(3 dB)
Typical
current
consumption
Cable*
NC-1-05
Passive wideband
hydrophone (no
preamplifier)
• Vessel with very low
level of noise (below
-110 dBV).
• Sensors close to the
vessel (approx. 300 m)
• For positioning
systems with Slant
Range/pinger (one
passive hydrophone
is necessary for
transmission).
33-60 KHz 0.0 mA
Blue
NC-1-05
+
NC-2-02
Passive
hydrophone
+ Wideband
preamplifier box
• Vessel with normal
level of noise (below
-100 dBV).
• Large number of
sensors.†
• Use at great depths (>
500 m).
• Gain configurable (Low
or High)
• Filters configurable (38
and/or 50kHz).
• Low noise environment
between passive
hydrophone and
wideband preamplifier
box
33-60 KHz 25-29 mA
Blue
NC-1-07
Active hydrophone
(integrated
preamplifier)
• Vessel with normal
level of noise (below
-100 dBV).
• Limited number of
sensors.†
• No filtering options.
• Not used for
positioning system
41-44 KHz 4-6 mA
Green
23
Summary of Contents for Scala2
Page 1: ...Scala2 User Manual...
Page 2: ......
Page 20: ...Scala2 Version 5 Installation 19...
Page 28: ...Scala2 Version 5 System Configuration Single Trawl Gear Twin Trawl Gear Triple Trawl Gear 27...
Page 29: ...Scala2 Version 5 System Configuration Quadruple Trawl Gear Twin Outrigger Trawl Gear 28...
Page 30: ...Scala2 Version 5 System Configuration Port Seine Gear Starboard Seine Gear 29...
Page 69: ...Scala2 Version 5 System Configuration 68...
Page 105: ...Scala2 Version 5 Display Configuration 104...
Page 122: ...Scala2 Version 5 Display Configuration 121...
Page 156: ...Scala2 Version 5 Maintenance and Troubleshooting c Double click UninstallScala command 155...