262391
194
Revision A
2.
Shut down the engine, and remove the key from the ignition.
3.
Open the left driveshield. For instructions, refer to
3.3.1 Opening Driveshields, page 23
.
1004092
A
Figure 4.207: Left Side of Rotary Header
4.
Clean the area around dipstick (A).
5.
Remove dipstick using a 22 mm socket.
6.
Ensure the lubricant level is to the full line on the dipstick.
7.
If necessary, add gear lubricant through dipstick hole (A).
Refer to the manual
’
s inside back cover for lubricant
information.
8.
Reinstall the dipstick and tighten it.
9.
Close the left driveshield. For instructions, refer to
.
Draining Lubricant from Cutterbar
–
Conditioner Drive Gearbox (T-Gearbox)
DANGER
To prevent bodily injury or death from the unexpected startup of the machine, always stop the engine and remove the
key from the ignition before leaving the operator
’
s seat.
DANGER
Ensure that all bystanders have cleared the area.
IMPORTANT:
Drain the gearbox lubricant when the lubricant is warm. If the lubricant is cold, idle the machine for approximately
10 minutes prior to draining.
1.
Lower the header fully.
2.
Shut down the engine, and remove the key from the ignition.
3.
Open the cutterbar doors. For instructions, refer to
3.4.1 Opening Cutterbar Doors, page 26
1011078
A
B
Figure 4.208: Vertical Driveshield
4.
Remove four M10 hex flange head bolts (A) and vertical
driveshield (B).