262391
184
Revision A
1022898
A
B
C
D
Figure 4.191: Conditioner Drive
4.
Turn jam nut (A) counterclockwise to unlock tension
adjustment.
5.
Turn jam nut (A) and adjuster nut (B) counterclockwise to
fully collapse tensioner spring (C) and release the tension
from conditioner drive belt (D).
6.
Remove drive belt (D).
Installing Conditioner Drive Belt
DANGER
To avoid bodily injury or death from unexpected startup of the machine, always stop the engine and remove the key
from the ignition before leaving the operator
’
s seat for any reason.
DANGER
Ensure that all bystanders have cleared the area.
1.
Lower the header fully.
2.
Shut down the engine, and remove the key from the ignition.
3.
Remove the left driveshield. For instructions, refer to
Removing Driveshields, page 171
.