262391
124
Revision A
1026451
A
B
C
D
Figure 4.77: Change Tool and Gauge
7.
Remove gauge (A) from change tool (B).
NOTE:
Section (C) of the gauge is used to check the material
thickness of the retaining bolts; section (D) of the gauge is
used to check the outer radius of the quick change plate.
1026429
A
B
Figure 4.78: Gauge and Quick Change Plate
8.
Thoroughly clean the area around and between the
retaining bolt and the quick change plate.
9.
Place gauge (A) against the retaining bolt of the quick
change plate (B) as far as it will go.
1026430
A
B
Figure 4.79: Gauge and Change Plate Aligned
•
If the outer radius of quick change plate (B) aligns with or
is outside the outer radius of gauge (A), the quick change
plate has not yet reached its wear limit.
•
If the outer radius of the quick change plate (B) does
NOT
align with the outer radius of gauge (A), the quick
change plate must be replaced.