TROUBLESHOOTING
* See your MacDon Dealer
** Refer to Windrower Technical Manual
Form 169469/169470/169471
213
Revision E
SYMPTOM PROBLEM
SOLUTION
SECTION
Air Conditioning Cools
Intermittently.
Compressor clutch slipping.
Contact MacDon Dealer.
*
Unit icing up due to thermostat adjusted too
low.
Adjust thermostat.
**
Unit icing up due to:
Excessive moisture in system.
Contact MacDon Dealer.
*
Incorrect super-heat adjustment in
expansion valve.
Thermostat defective.
Defective blower switch or blower motor.
Partially open, improper ground, or loose
connection in compressor clutch coil.
Windows Fog Up.
High humidity.
Run A/C to dehumidify air and
heater to control temperature.
5.10.3
8.8 OPERATOR’S
STATION
SYMPTOM PROBLEM
SOLUTION
SECTION
Rough Ride.
Seat suspension not adjusted for Operator's
weight.
Adjust seat suspension.
5.3
High air pressure in tires.
Deflate to proper pressure.
7.12.1 and
7.12.2