MAINTENANCE AND SERVICING
169469/169470/169471
157
Revision E
e. Place a drain pan (about 8 U.S. gallons [30 liters])
under the engine and radiator.
f. Remove the radiator cap, and open radiator drain
valve (B) on the engine side of the radiator lower
tank. Use a deflector or a hose to prevent coolant
running onto frame.
g. Close the heater shut-off valve (C), and
disconnect hose on heater side of valve.
h. Open valve to drain the block.
i. When system is drained, replace hose on valve
(C), and close radiator drain valve (B).
j. Fill system with clean water through the radiator,
and replace radiator cap.
k. Open heater shut-off valve (C).
l. Start engine, and turn temperature control knob to
high. Run engine until normal operating
temperature is reached.
m. Stop engine, and drain water out before rust or
sediment settles. See steps d. to h.
n. Close drain valves, and fill system with a solution
of clean water and a heavy duty radiator cleaner.
Follow instructions provided with cleaner.
o. After using cleaner solution, again flush system
with clean water. Inspect radiator, hoses and
fittings for leaks.
p. Close drain valves, and fill system through
radiator. Use Ethylene Glycol with SCA equal
parts with high quality, soft, de-ionized or distilled
water as recommended by the supplier. System
capacity is 5.3 U.S. Gallons (20 liters).
q. Close radiator cap tightly.
r. Remove cap (D) from recovery tank (E), and add
coolant until one-half full.
s. Move maintenance platform to working position,
and close engine compartment hood.
B
D
E
C
Summary of Contents for M205 2012
Page 1: ...M205 Self Propelled Windrower OPERATOR S MANUAL Part 169469 Rev E 25 ...
Page 11: ...SAFETY 169469 169470 169471 9 Revision E ...
Page 13: ...SAFETY 169469 169470 169471 11 Revision E Safety Sign Locations cont d ...
Page 186: ...MAINTENANCE AND SERVICING 169469 169470 169471 184 Revision E 7 10 13 3 Fuse Box Decal ...