WavePro 7 Zi and Zi-A Oscilloscopes
129
WP7Zi-GSM-E RevB
In Dual Parameter Compare mode, your X-Stream oscilloscope can take
parameter results measured on two different waveforms and compare
them to each other. If desired, set your test to be true if
Any
or
All
waveforms fit the criteria set by the comparison condition. Setups are
conveniently shown in the Summary box of the
Qx
dialog as follows:
M
ASK
T
ESTS
Mask testing can be done using an existing mask, or by using a mask
created from your actual waveform, with vertical and horizontal tolerances
that you define. Existing masks can be loaded from a floppy disk or from a
network.
You can set your mask test to be True for waveforms All In, All Out, Any In,
or Any Out. For example, if you select All In, the test becomes False if even
a single waveform falls outside the mask.
Masks that you create from your waveform can be confined to just a
portion of the trace by use of a measure gate. Refer to the
Measure Gate
online help topic for more information on how this feature works.
A
CTIONS
By touching the
Stop Test
checkbox in the
Actions
dialog, you can set up
the test to end after a predetermined number of sweeps that you decide.