POWER CORE User Manual
Version: V6.0.0/5
313/459
18. Configuring Custom Logical Behaviour
18.12 Logic -> IMP
An
Impulse
element can be used to turn an input control signal into seven different outputs.
General Parameters
IMP
Reference name for the element.
In
The input control signal.
Pulsetime On (1/10 sec)
Enter the pulse time in degrees of 1/10 second. Note that this time is approximate.
Pulsetime Off (1/10 sec)
Enter the delay time in degrees of 1/10 second. Note that this time is approximate.
Re-trigger
If enabled, the IMP may be re-triggered during the "on" cycle, leading to a longer "on"
period.
The seven control signals appear in the “Logic -> <GroupName> -> IMP” branch of the 'Tree Selection' window:
Switch On Out
Becomes a logical “1” when a rising edge is supplied to the input. The status remains set
for the duration of the
Pulsetime On
.
Neg Switch On Out
Negative output of the
Switch On Out
.
Switch Off Out
Becomes a logical “1” when a falling edge is supplied to the input. The status remains set
for the duration of the
Pulsetime Off
.
Neg Switch Off Out
Negative output of the
Switch Off Out
.
Switch OR (On/Off) Out
Becomes a logical “1” if the
Switch On Out
is true OR the
Switch Off Out
is true.
Neg Switch OR (On/Off) Out
Negative output of the
Switch OR (On/Off) Out
.
Switch OR (In/On/Off) Out
Becomes a logical “1” if the input is true OR the
Switch On Out
is true OR the
Switch Off
Out
is true.