POWER CORE User Manual
Version: V6.0.0/5
272/459
15. Connecting a VisTool MK2 PC
15.10 Timers
Open the "System -> Definition -> Parameter = Timer" branch of the 'Tree Definition' to set options for the six
timers which you can display within VisTool.
Parameter
Timer – reference name for the element.
Time N Name
Enter a reference name for the timer.
Timer N Start
Assigns a control signal to start the timer. The timer will start from its current position.
If you want a key to always start the timer from 00:00:00:00, assign the same key to both
the
Timer N Start
and
Timer N Reset
functions.
Timer NStop
Assigns a control signal to stop the timer.
Timer N Reset
Assigns a control input signal to reset the timer to 00:00:00:00.
Timer N Restart
Assigns a control input signal to restart the timer from its current position.
The following control outputs appear under “Logic -> Definition -> Parameter Timer” of the 'Tree Selection' window:
Timer N Run
Active when the timer is running. Can be used to illuminate the MF Key controlling the
timer.
Timer N Alarm
Active when the timer alarm is active.