Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
Eco Mode
Settings
ECO Mode
• This parameter allows the technician to
set up a temperature to be maintained
in case of a temporary non utilization of
the espresso machine.
• It is possible to set this parameter also
during the normal operation of the
machine by pressing T1 and T2 at the
same time.
After accessing the “Technical” programming menu and entering the password, use the buttons
T1
and
T2
until the following screen is displayed.
Press the T3 button
to enter the menu.
Press the T3 button
to enter the menu, move between the parameters with the buttons T1
and
T2
to set the desired temperature, press the T3 button
to confirm the value.
Press the T3 button
to enter the menu, move between the parameters with the buttons T1
and
T2
to set the desired time (in minutes), press the T3 button
to confirm the value. A value of
“
0
” (zero) disables the Eco Mode parameter.
To exit the submenu move between the parameters using the buttons T1
and T2
until the exit
submenu is displayed. Press the T3 button
to exit the submenu.
Enter Password
******
Eco Mode
Settings
Eco Mode Temp
-10.0
°
C
Auto Eco Time
30
Eco Mode
Exit