EN
85
Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
Press the T3 button
to enter the menu, move using the buttons
T1
and T2
to select
YES
or
NO
, press the T3 button
to confirm the option.
Press the T3 button
to enter the menu, move with the buttons
T1
and T2
to set the
desired time, press the T3 button
to confirm the value.
Press the T3 button
to enter the menu, move using the buttons
T1
and T2
to select
WITH PUMP
or
WITHOUT PUMP
, press the T3 button
to confirm the option.
Press the T3 button
to enter the menu, move using the buttons
T1
and T2
to select
HIGH
or
LOW
, press the T3 button
to confirm the option.
To exit the submenu move between the parameters using the buttons
T1
and T2
until the exit
submenu is displayed. Press the T3 button
to exit the submenu.
Steam Boiler
Settings
Fill With Pump
WITH PUMP
Autofill Timeout
10 min
SB Settings
Exit
• The parameter filling WITH PUMP allows
the technician to select the activation of
the water pump during the automatic
filling cycle of the service boiler.
• Only under unusual circumstances would
the option of “WITHOUT PUMP” be
chosen.
• The electronics installed in this espresso
machine give priority to the brew boiler for
pressure. The activation of the auto-fill cy-
cle during the brewing process can reduce
the overall dispensing pressure in the brew
boiler.
• During the auto-fill cycle, if a brew cycle is
chosen, the auto-fill cycle is delayed until
all brew cycles are complete.
Steam Boiler
THE STEAM BOILER CONTAINS WATER AT ELEVATED TEMPERATURES. WATER TEMPERATURE OVER 52°C CAN
CAUSE SEVERE BURNS INSTANTLY OR DEATH FROM SCALDING.
DANGER
Fill During Brew
YES
Level Sensitiv.
HIGH
6
8
9
10
7
Summary of Contents for Linea PB
Page 111: ...EN 111 ...
Page 112: ......