STE User’s Manual
Installation
Rel. 2.6
2-5
must be done to obtain any services not presently available. Abide by local regulations for phone
installations and maintenance.
•
Last, you must also order your EFF card KOV-14L or KSV-21 or you use your older BFF KOV-14,
KOV-15 or SOV-16, the FORTEZZA PLUS
KRYPTON™
ENHANCED CRYPTOCARD (Paragraph
Next, before you can begin your STE installation, you must have all the following required components:
•
STE - complete (see Paragraph
for component lists for each STE type).
•
Cryptography Card
•
Telephone line*
•
Power Source
* You may need a (optional) Network Termination Device.
Finally, before you proceed with the installation, please take the time to review this manual, especially
on
Controls Indicators and Interfaces
.
2-3.1
Power Port Pre-installation Requirements
The Power Port pre-installation requirements apply to all STEs.
The
POWER PORT
, a DB-9 connector, is located on the rear of the STEs. Pin assignments are shown in
. The STE is normally installed using the STE Power Supply shipped with the unit. The Power
Supply DC cord (DB-9 to power supply) is 6 feet long. The 6-foot AC cord shipped with the supply, for
use in the USA, is an IEC320 plug on the supply side and a standard 3-prong 110V plug on the other end.
Users with different requirements must provide an AC cord with an IEC320 plug for the power supply and
the power plug required for their site. However, in some installations, such as rack or stacked installation
with multiple STEs, an external supply may be desired. See
for the STE power requirements.
Table 2-8. Power Port Pin-out
Pin
Signal Name
Pin
Signal Name
1 Chassis
Ground
6 Common
2
+5 Volts
7
+12 Volts
3 +5
Volts
8 Common
4
Common
9
+5 Volts Sense (optional)
5
-12 Volts
Shell
Chassis Ground
NOTE
The +5 Volt sense is connected to +5 Volts within the STE.
Table 2-9. Power Requirements
Signal Regulation* Maximum
Load
+5 Volts
-2%, +5%
3.0 Amps
+12 Volts
-5%, +5%
1.0 Amp
-12 Volts
-10%, +10%
0.3 Amps
NOTE
* = peak-to-peak ripple voltage, including spikes shall not exceed 2% of nominal
voltage.
2-3.2
Console Port Pre-Installation Requirement
This requirement applies to the the following STE configuration types: the CEU; Data STE; STE-R; STE-
RI; and the STE-RT.
Summary of Contents for CEU
Page 2: ...Copyright 2006 L 3 Communications Corporation ...
Page 26: ...List of Tables STE User s Manual xiv Rel 2 6 This page intentionally left blank ...
Page 32: ...Introduction STE User s Manual 1 6 Rel 2 6 This page intentionally left blank ...
Page 132: ......
Page 181: ...STE User s Manual Crypto Card Management Rel 2 6 6 25 ...
Page 182: ......
Page 210: ...Calls STE User s Manual 7 28 Rel 2 6 This page intentionally left blank ...
Page 234: ...Remote Control Operations STE User s Manual 8 24 Rel 2 6 This page intentionally left blank ...
Page 258: ...8510 Capabilities STE User s Manual 9 24 Rel 2 6 This page intentionally left blank ...
Page 284: ...User Maintenance STE User s Manual 11 6 Rel 2 6 This page intentionally left blank ...
Page 288: ...Notes STE User s Manual 12 4 Rel 2 6 12 4 CE DECLARATION OF CONFORMITY ...
Page 306: ...Index STE User s Manual Index 18 Rel 2 6 This page intentionally left blank ...
Page 308: ...Rel 2 6 FP 2 FO 2 User Tree ...
Page 311: ......