Advanced Configuration
42
2. Configure VLAN 100, an isolation domain, as shown in Figure 39.
Set port 1 and port 2 to Tag ports and add them to VLAN 100. Enable PVLAN on the two
ports.
Set port 3 and port 4 to Untag ports and add them to VLAN 100.
3. Configure VLAN 200, an isolation domain, as shown in Figure 39.
Set port 1 and port 2 to Tag ports and add them to VLAN 200. Enable PVLAN on the two
ports.
Set port 5 and port 6 to Untag ports and add them to VLAN 200.
4. Set VLAN300, VLAN100 and VLAN200 to PVLAN members, as shown in Figure 40.
6.4 Port Mirroring
6.4.1 Overview
With port mirroring function, the switch copies all received or transmitted data frames in a
port (mirroring source port) to another port (mirroring destination port). The mirroring
destination port is connected to a protocol analyzer or RMON monitor for network monitoring,
management, and fault diagnosis.
6.4.2 Description
A switch supports only one mirroring destination port but multiple source ports.
Multiple source ports can be either in the same VLAN, or in different VLANs. Mirroring
source port and destination port can be in the same VLAN or in different VLANs.
The source port and destination port cannot be the same port.
Caution:
A mirroring source or destination port cannot be added to a Trunk group,while the port
added to a Trunk group cannot be set to a mirroring destination or source port.
A mirroring source or destination port cannot be set to a redundant port, while a redundant
port cannot be set to a mirroring source or destination port.
Summary of Contents for SICOM3024P
Page 13: ...Product Introduction 6 management software and SNMP network monitoring...
Page 25: ...Device Status 18 Figure 15 System Operating Information SICOM3024...
Page 73: ...Advanced Configuration 66 Figure 67 Setting ACL Entry Parameters Group 2...
Page 145: ...Advanced Configuration 138 Figure 137 Dynamic Unicast FDB Table...