Advanced Configuration
133
Owner
Range: 1~32 characters
Function: Configure the name of the alarm entry.
Data Source
Function: Select the port whose information is to be monitored.
Stat Group
Options: indexes of entries in the RMON statistics table.
Function: Select the statistics entry whose port is to be monitored.
Sampling Type
Options: Absolute/Delta
Default: Absolute
Function: Absolute indicates absolute value-based sampling. The value of the variable is
directly extracted when the end of a sampling period approaches. Delta indicates change
value-based sampling. The change value of the variable in the sampling period is extracted
when the end of the period approaches.
Alarm Type
Options: RisingAlarm/FallingAlarm/RisOrFallAlarm
Default: RisingAlarm
Function: Select the alarm type, including the rising edge alarm, falling edge alarm, and both
rising edge and falling edge alarms.
Sampling Space
Range: 1~65535
Function: Configure the sampling period. The value should be identical with that in the
history table.
Rising Threshold
Range: 0~65535
Function: Configure the rising edge threshold. When the sampling value exceeds the
threshold and the alarm type is set to RisingAlarm or RisOrFallAlarm, an alarm is generated
and the rising event index is triggered.
Falling Threshold
Summary of Contents for SICOM3024P
Page 13: ...Product Introduction 6 management software and SNMP network monitoring...
Page 25: ...Device Status 18 Figure 15 System Operating Information SICOM3024...
Page 73: ...Advanced Configuration 66 Figure 67 Setting ACL Entry Parameters Group 2...
Page 145: ...Advanced Configuration 138 Figure 137 Dynamic Unicast FDB Table...