Advanced Configuration
116
Function: Enable or disable the SNTP server function.
time zone
Options: 0, +1, +2, +3, +4, +5, +6, +7, +8, +9, +10, +11, +12, +13, -1, -2, -3, -4, -5, -6, -7, -8,
-9, -10, -11, and -12
Default: +8
Function: Select the server time zone.
6.19 Alarm
6.19.1 Overview
This series switches support the following types of alarms:
Power alarm: If the function is enabled, then an alarm will be generated for a single power
input.
Temperature alarm: If the function is enabled, then an alarm will be generated when the
temperature is equal to or lower than the lower limit or equal to or higher than the higher
limit.
IP/MAC conflict alarm: If the function is enabled, then an alarm will be generated for an
IP/MAC conflict.
Port alarm: If the function is enabled, then an alarm will be generated for the port in link
down state.
Ring alarm: If the function is enabled, then an alarm will be generated for an open ring.
Caution:
Only the master station of a DT ring supports the ring alarm function.
SICOM3024P supports Power alarm, Temperature alarm, IP,MAC conflict alarm, Port alarm
and Ring alarm.
SICOM3048 supports IP,MAC conflict alarm, Port alarm and Ring alarm.
SICOM3024 supports Power alarm, IP,MAC conflict alarm, Port alarm and Ring alarm.
6.19.2 Web Configuration
1. Set alarm parameters, as shown in the following figures.
Summary of Contents for SICOM3024P
Page 13: ...Product Introduction 6 management software and SNMP network monitoring...
Page 25: ...Device Status 18 Figure 15 System Operating Information SICOM3024...
Page 73: ...Advanced Configuration 66 Figure 67 Setting ACL Entry Parameters Group 2...
Page 145: ...Advanced Configuration 138 Figure 137 Dynamic Unicast FDB Table...