Advanced Configuration
123
The timers should comply with the following rules: Hold timer<Join timer, 2*Join timer<Leave
timer, and Leave timer<LeaveAll timer.
6.21.4 Web Configuration
1. Enable the global GMRP protocol, as shown in the following figure.
Figure 121 GMRP Global Configuration
GMRP State
Options: Enable/Disable
Default: Disable
Function: Enable or disable the global GMRP function. The function and IGMP Snooping
cannot be used at the same time.
LeaveAll Timer
Range: 100ms~327600ms
Default: 10000ms
Function: Set the interval for sending LeaveAll messages. The value must be a multiple of
100.
Description: If the LeaveAll timers of different devices expire at the same time, multiple
LeaveAll messages will be sent simultaneously, increasing unnecessary packets. To prevent
this problem, the actual timeout of a LeaveAll timer is a random value between the specified
value and 1.5 times the specified value.
2. Configure GMPR function on each port, as shown in the following figure.
Summary of Contents for SICOM3024P
Page 13: ...Product Introduction 6 management software and SNMP network monitoring...
Page 25: ...Device Status 18 Figure 15 System Operating Information SICOM3024...
Page 73: ...Advanced Configuration 66 Figure 67 Setting ACL Entry Parameters Group 2...
Page 145: ...Advanced Configuration 138 Figure 137 Dynamic Unicast FDB Table...