Guidelines, Norms and Standards
Operating manual INVEOR
87
9.3
Standards and guidelines
The following specifically apply:
– Directive on Electromagnetic Compatibility
(Directive 2004/108/EC of the Council EN 61800-3:2004)
– Low Voltage Directive
(Directive 2006/95/EC of the Council EN 61800-5-1:2003)
– Product standards list
9.4
Required markings for UL
Required Markings
For installation on industrial machines in accordance with the Standard for
Industrial Machinery NFPA79 only.
Maximum Ambient Temperature:
Electronic Adapter
Ambient
INV MA 4 1.5
ADP MA WDM
35°C
INV MB 4 2.2
ADP MB WDM
45°C
INV MB 4 3.0
ADP MB WDM
40°C
INV MB 4 4.0
ADP MB WDM
35°C
INV MC 4 5.5
ADP MC WDM
40°C
INV MC 4 7.5
ADP MC WDM
35°C
Internal Overload Protection Operates within 60 seconds when reaching
150% of the Motor Full Load Current.
Suitable For Use On A Circuit Capable Of Delivering Not More Than 5kA rms
Symmetrical Amperes, 400 Volts Maximum When Protected by Fuses.