![Kostal INVEOR MA Operating Manual Download Page 58](http://html1.mh-extra.com/html/kostal/inveor-ma/inveor-ma_operating-manual_1999368058.webp)
Parameters
58
Operating manual INVEOR
4.034/4.064
Alx physical minimum
Unit:
min:-10,000
max.:+10,000
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (
to
be entered!
)
Relationship to
parameter:
4,033/4,063
4,035/4,065
Selection of the lower limit of a physical value to be displayed.
4.035/4.065
Alx physical maximum
Unit:
min:-10,000
max.:+10,000
Parameter manual:
p. xy
Transfer status:
2
def.: 100
own value (
to
be entered!
)
Relationship to
parameter:
4,033/4,063
4,034/4,064
Selection of the upper limit of a physical value to be displayed.
5.3.6
Digital inputs
4.110 to 4.113
DIx inverted
Unit: integer
min: 0
max.: 1
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (
to
be entered!
)
Relationship to
parameter:
This parameter can be used to invert the digital input.
0 = disable
1 = enable