Parameters
72
Operating manual INVEOR
5.4.5
Squared characteristic
34.120
Squared characteristic
Unit: integer
min: 0
max.: 1
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (
to
be entered!
)
Relationship to
parameter:
34,121
Only for asynchronous motors.
The quadratic characteristic curve function can be activated here.
0 = disable
1 = enable
34.121
Flux compensation
Unit: %
min: 0
max.: 100
Parameter manual:
p. xy
Transfer status:
2
def.: 50
own value (
to
be entered!
)
Relationship to
parameter:
34,120
Only for asynchronous motors.
The percentage by which the flux is to be reduced can be set here.
An overvoltage shutdown can occur if there are any major changes in
operation.
5.4.6
Synchronous motor controller data
34.225
Field weakening
Unit: integer
min: 0
max.: 1
Parameter manual:
p. xy
Transfer status:
2
Def.: 0
own value
(
to be
entered!
)
Relationship to
parameter:
For synchronous motors only.
0 = disable, the motor cannot be run in the field weakening.
1 = enable, the motor can be placed in the field weakening until the inverter
has reached its current limit or the maximum permissible EMK.
Summary of Contents for INVEOR MA
Page 1: ...Operating manual INVEOR Betriebsanleitung_INVEOR_A5 indd 1 28 02 11 10 33...
Page 91: ...Guidelines Norms and Standards Operating manual INVEOR 91...
Page 92: ...Guidelines Norms and Standards 92 Operating manual INVEOR...
Page 93: ...Guidelines Norms and Standards Operating manual INVEOR 93...