Start-up steps
Parameterising is possible prior to installation.
Parameterisation can be performed before the drive
control is installed in the engine.
The drive control has a 24 V low-voltage input for this
purpose, which can supply the electric system without
requiring mains power.
The start-up can be performed using a PC communication cable USB at plug
M12 with integrated interface converter RS485/RS232 (article no. 10023950)
or using the INVEOR manual control unit MMI with connection cable RJ11 at
plug M12 (article no. 10004768).
Start-up using the PC:
Install the INVEORpc software (you can obtain programming software from
KOSTAL free of charge).
Connect the PC to the M12 plug M1 with the optional connection cable.
Load or determine the motor data record (parameters 33,030 to 33,050); it
may be necessary to optimise the speed control (parameters 34,100 to
34,101).
Make the application settings (ramps, inputs, outputs, target values etc.).
Optional: Define an access level (1 – MMI, 2 – user, 3 – manufacturer).
Please see also the quickstart guide in chapter 9.5.
In order to ensure an ideal operating structure for the PC software, the
parameters are classified into different access levels. There are the following
levels:
1. Manual control unit: – the drive control is programmed using the manual
control unit
2. User: – the basic parameters can be programmed into the drive control
using the PC software
3. Manufacturer: – an extended selection of parameters can be programmed
into the drive control using the PC software
Summary of Contents for INVEOR MA
Page 1: ...Operating manual INVEOR Betriebsanleitung_INVEOR_A5 indd 1 28 02 11 10 33...
Page 91: ...Guidelines Norms and Standards Operating manual INVEOR 91...
Page 92: ...Guidelines Norms and Standards 92 Operating manual INVEOR...
Page 93: ...Guidelines Norms and Standards Operating manual INVEOR 93...