Parameters
Operating manual INVEOR
67
33.110
Motor voltage
Unit: V
min: 0
max.: 680
Parameter manual:
p. xy
Transfer status:
1
def.: 0
own value (
to
be entered!
)
Relationship to
parameter:
Only for asynchronous motors.
This is used to set the nominal motor voltage U
M,N
for either the star or
triangle connection.
33.111
Motor cos phi
Unit: 1
min: 0.5
max.: 1
Parameter manual:
p. xy
Transfer status:
1
def.: 0
own value (
to
be entered!
)
Relationship to
parameter:
Only for asynchronous motors.
The value from the motor's type plate data has to be entered here for the
power factor cosphi.
33.200
Stator inductance
Unit: H
min: 0
max.: 100
Parameter manual:
p. xy
Transfer status:
1
def.: 0
Own value (
to
be entered!
)
Relationship to
parameter:
For synchronous motors only.
The stator inductivity can be optimised here if the automatically determined
value (motor identification) is insufficient.
33.201
Nominal flux
Unit: mVs
min: 0
max.: 5000
Parameter manual:
p. xy
Transfer status:
1
def.: 0
Own value (
to
be entered!
)
Relationship to
parameter:
For synchronous motors only.
The nominal flux can be optimised here if the automatically determined value
(motor identification) is insufficient.
Summary of Contents for INVEOR MA
Page 1: ...Operating manual INVEOR Betriebsanleitung_INVEOR_A5 indd 1 28 02 11 10 33...
Page 91: ...Guidelines Norms and Standards Operating manual INVEOR 91...
Page 92: ...Guidelines Norms and Standards 92 Operating manual INVEOR...
Page 93: ...Guidelines Norms and Standards Operating manual INVEOR 93...